GESO SYSTEMS' commissioning service cases:
Company name: Xinjiang Xindai Petroleum Technology Co., Ltd.
Address: 2-3-3, Yingmaili Operation Area, Kuqa City
Model: BAE-355 FC+, 1 unit, GSN99-1500, 1 unit
Debugging time: 2024.6.26
Debugging result: The startup and debugging are qualified, and the startup and debugging form needs to be signed by the general manager of Xindai Petroleum Technology Co., Ltd.
Inspection equipment
Address: Dina Operation Area, Kuqa City
Model: BAE-355FC+, 3 units, GSN99-1500, 3 units
Inspection results: The operating time of the three air compressors is 930 hours, 1179 hours, and 1170 hours respectively. The air compressor has not yet undergone the first maintenance (500). The customer has been notified that the air compressor should be used in a standardized manner and the wearing parts should be replaced regularly according to the instructions. The oil and gas barrel covers of the three air compressors have different degrees of oil leakage. According to on-site observations, it is initially speculated that the oil separator core only has a paper gasket on the top, and there is no oil leakage below. The final result needs to be confirmed with the factory.